switchcraft
MMVP – VIDEO PATCH HD 3GHZ 48X2 1ru

switchcraft

switchcraft
 

Video Patchcord da 3 Ghz

VPP Video Patchbay Series

 

The VPP Series video patchbays offer a wide variety of options for video patching. The HD Series exceeds SMPTE 292M and SMPTE 424M specifications for high definition video signaling, covering a bandwidth range from DC to 3.0GHz. The SD Series is perfect for serial digital, with a bandwidth from DC to 1.75GHz. Both come in either terminated or non-terminated, 24 or 26 jacks, 1.75" or 3.5" heights.

Features and Benefits

• HD Series rated from DC to 3.0GHz
• SD Series has a bandwidth from DC to 1.75GHz
• Black thermoplastic modules insulate jacks from chassis
• Jacks feature rugged heavy duty housings

VPP Ordering Information
 

Park Number Type of Jack No. of Jacks Height Description
VPP24K1HD*75T HD 24 1.75" Terminated
VPP24K1HD*NT HD 24 1.75" Non-terminated
VPP24K1SD*75T SD 24 1.75" Terminated
VPP24K1SD*NT SD 24 1.75" Non-terminated
VPP26K1HD*75T HD 26 1.75" Terminated
VPP26K1HD*NT HD 26 1.75" Non-terminated
VPP26K1SD*75T SD 26 1.75" Terminated
VPP26K1SD*NT SD 26 1.75" Non-terminated
VPP24K3HD*75T HD 24 3.5" Terminated
VPP24K3HD*NT HD 24 3.5" Non-terminated
VPP24K3SD*75T SD 24 3.5" Terminated
VPP24K3SD*NT SD 24 3.5" Non-terminated
VPP26K3HD*75T HD 26 3.5" Terminated
VPP26K3HD*NT HD 26 3.5" Non-terminated
VPP26K3SD*75T SD 26 3.5" Terminated
VPP26K3SD*NT SD 26 3.5" Non-terminated
 

*Add "N" for non-normalled version

Click here to view Drawings & Charts
(you will need to have Adobe Acrobat installed on your system to do this)

Patch Panel Video switchcraft

Video Jack Specifications

Electrical
Rated Bandwidth: 3.0 GHz (HD), 1.75 GHz (SD)
Characteristic Impedance: 75 ohms
Return Loss: See typical chart
Insertion Loss: See typical chart
Contact Resistance: Less than 20 milliohms
Termination Resistance: 75 ohm, ±1%
Center Conductor: Accepts .090 pin diameter

Mechanical
Mechanical Shock: Per MIL-STD-202, Method 213,
Test condition I
Vibration: Per MIL-STD-202, Method 201
Life Cycle: 30,000

Material
Housing: Zinc alloy, nickel plated
Center Contacts: Copper alloy, gold plated
Switching Springs: Copper alloy, gold plated
Grounding Contacts: Copper alloy, gold plated
Insulators: Thermoplastic, UL 94V-0 rated

Environmental
Operating Temperature: – 40ºC to 65ºC
Storage Temperature: – 55ºC to 85ºC
Thermal Shock: Per MIL-STD-202, Method 107
Moisture and Humidity: Per MIL-STD-202, Method 106

Ordering – Individual Jacks

Part Number Type Description
VJHD*75TZ HD Terminated
VJHD*NTZ HD Non-terminated
VJSD*75TZ SD Terminated
VJSD*NTZ SD Non-terminated

*Add "N" for non-normalled version

MidSize Video Patchbay Series

Patch Panel Video switchcraft

Dual Jack Series


Patch Panel Video switchcraft

Dual Jack with Top Row of Single Monitoring Jack Series


Patch Panel Video switchcraft

Single Jack Series


MidSize Series:

Switchcraft MidSize Series video patchbays offer outstanding performance in high-density 19 inch rack panels. All units are offered with the options of dual and/or single jacks, 32 or 34 jacks in a row. The panels are also available in 1RU, 1.5RU, and 2RU versions.

Also now available are: Switchcraft MidSize RGB/RGBS/and RGBHV Series.

The jacks are rated from DC to 3 GHz, which exceed SMPTE 292M and 424M requirements, and are available in multiple normaled and 75 Ohm terminated configurations.

Features and Benefits

• Midsize video jacks rated from DC to 3 GHz
• 32 dual or single midsize jacks mounted either 1RU, 1.5RU or 2RU panels
• Available in terminated or non-terminated configurations

Patchbay Specifications

Material
Frame: Aluminum, black anodized
Designation Strips: Vinylite, white
Designation Strip Covers: Lexan, transparent
Jack Inserts: Thermoplastic, UL 94V-0 rated

Part Numbers and Ordering Information
Continue to scroll down for part number charts or click here for the part number matrices.

Ordering Information for Loaded MVP Series Patchbays (Dual Jacks)

 

Park Number Height No. of Jacks Configuration
MVP32K175T 1RU 2 Rows of 32 Normaled/75 Ohm Term.
MVP32K1N75T 1RU 2 Rows of 32 Non-Normal/75 Ohm Term.
MVP32K1NNT 1RU 2 Rows of 32 Non-Normal/Non-Term.
MVP32K1NT 1RU 2 Rows of 32 Normal/Non-Term.
MVP32K275T 1.5RU 2 Rows of 32 Normaled/75 Ohm Term.
MVP32K2N75T 1.5RU 2 Rows of 32 Non-Normal/75 Ohm Term.
MVP32K2NNT 1.5RU 2 Rows of 32 Non-Normal/Non-Term.
MVP32K2NT 1.5RU 2 Rows of 32 Normal/Non-Term.
MVP32K375T 2RU 2 Rows of 32 Normaled/75 Ohm Term.
MVP32K3N75T 2RU 2 Rows of 32 Non-Normal/75 Ohm Term.
MVP32K3NNT 2RU 2 Rows of 32 Non-Normal/Non-Term.
MVP32K3NT 2RU 2 Rows of 32 Normal/Non-Term.
MVP34K175T 1RU 2 Rows of 34 Normaled/75 Ohm Term.
MVP34K1N75T 1RU 2 Rows of 34 Non-Normal/75 Ohm Term.
MVP34K1NNT 1RU 2 Rows of 34 Non-Normal/Non-Term.
MVP34K1NT 1RU 2 Rows of 34 Normal/Non-Term.
MVP34K275T 1.5RU 2 Rows of 34 Normaled/75 Ohm Term.
MVP34K2N75T 1.5RU 2 Rows of 34 Non-Normal/75 Ohm Term.
MVP34K2NNT 1.5RU 2 Rows of 34 Non-Normal/Non-Term.
MVP34K2NT 1.5RU 2 Rows of 34 Normal/Non-Term.
MVP34K375T 2RU 2 Rows of 34 Normaled/75 Ohm Term.
MVP34K3N75T 2RU 2 Rows of 34 Non-Normal/75 Ohm Term.
MVP34K3NNT 2RU 2 Rows of 34 Non-Normal/Non-Term.
MVP34K3NT 2RU 2 Rows of 34 Normal/Non-Term.

Patch Panel Video switchcraft

1RU

Patch Panel Video switchcraft

1.5RU

Patch Panel Video switchcraft

2RU


Ordering Information for Loaded MVPM Patchbays (Dual & Single Mix)

Part Number Height Rows of Gangs Single Row Jack Config. Dual Row Jack Config.
MVPM32K375T 2RU 3 Rows of 32 Single-75 Ohm Term. Dual-Normalled/75 Ohm Term.
MVPM32K3N75T 2RU 3 Rows of 32 Single-75 Ohm Non-Term. Dual-Normalled/Non-Term.
MVPM34K375T 2RU 3 Rows of 34 Single-75 Ohm Term. Dual-Normalled/75 Ohm Term.
MVPM34K3N75T 2RU 3 Rows of 34 Single-75 Ohm Non-Term. Dual-Normalled/ Non-Term.
MVPM32DK3S75T 2RU 3 Rows of 32 Single-75 Ohm Term. Single/75 Ohm Term.
MVPM32DK3SNT 2RU 3 Rows of 32 Single-75 Ohm Non-Term. Single/Non-Term.
MVPM34DK3S75T 2RU 3 Rows of 34 Single-75 Ohm Term. Single/75 Ohm Term.
MVPM34DK3SNT 2RU 3 Rows of 34 Single-75 Ohm Non-Term. Single/Non-Term.

Patch Panel Video switchcraft

2RU (MVPM)


 

Ordering Information for Loaded MVP Patchbays with all Single Jacks

 

One Row of Single Jacks
Park Number Height No. of Jacks Termination
MVP32SK1S75T 1RU 1 Row of 32 75 Ohm Terminated
MVP32SK1SNT 1RU 1 Row of 32 Non-Terminated
MVP32SK2S75T 1.5RU 1 Row of 32 75 Ohm Terminated
MVP32SK2SNT 1.5RU 1 Row of 32 Non-Terminated
MVP32SK3S75T 2RU 1 Row of 32 75 Ohm Terminated
MVP32SK3SNT 2RU 1 Row of 32 Non-Terminated
MVP34SK1S75T 1RU 1 Row of 34 75 Ohm Terminated
MVP34SK1SNT 1RU 1 Row of 34 Non-Terminated
MVP34SK2S75T 1.5RU 1 Row of 34 75 Ohm Terminated
MVP34SK2SNT 1.5RU 1 Row of 34 Non-Terminated
MVP34SK3S75T 2RU 1 Row of 34 75 Ohm Terminated
MVP34SK3SNT 2RU 1 Row of 34 Non-Terminated
Two Rows of Single Jacks
MVP32DK1S75T 1RU 2 Rows of 32 75 Ohm Terminated
MVP32DK1SNT 1RU 2 Rows of 32 Non-Terminated
MVP32DK2S75T 1.5RU 2 Rows of 32 75 Ohm Terminated
MVP32DK2SNT 1.5RU 2 Rows of 32 Non-Terminated
MVP32DK3S75T 2RU 2 Rows of 32 75 Ohm Terminated
MVP32DK3SNT 2RU 2 Rows of 32 Non-Terminated
MVP34DK1S75T 1RU 2 Rows of 34 75 Ohm Terminated
MVP34DK1SNT 1RU 2 Rows of 34 Non-Terminated
MVP34DK2S75T 1.5RU 2 Rows of 34 75 Ohm Terminated
MVP34DK2SNT 1.5RU 2 Rows of 34 Non-Terminated
MVP34DK3S75T 2RU 2 Rows of 34 75 Ohm Terminated
MVP34DK3SNT 2RU 2 Rows of 34 Non-Terminated

Patch Panel Video switchcraft

1RU

Patch Panel Video switchcraft

1.5RU

Patch Panel Video switchcraft

2RU


Ordering Information for Empty MVP & MVPM Panels

 

Park Number Height No. of Jacks Termination
MVP32K1FP 1RU 2 Rows of 32 No Tie Bar & Designation Strips Included
MVP32K2FP 1.5RU 2 Rows of 32 Tie Bar & Designation Strips Included
MVP32K3FP 2RU 2 Rows of 32 Tie Bar & Designation Strips Included
MVPM32K3FP 2RU 2 Rows of 32 Tie Bar & Designation Strips Included
MVP34K1FP 1RU 2 Rows of 34 No Tie Bar & Designation Strips Included
MVP34K2FP 1.5RU 2 Rows of 34 Tie Bar & Designation Strips Included
MVP34K3FP 2RU 2 Rows of 34 Tie Bar & Designation Strips Included
MVPM34K3FP 2RU 2 Rows of 34 Tie Bar & Designation Strips Included

Patch Panel Video switchcraft

1RU

Patch Panel Video switchcraft

1.5RU

Patch Panel Video switchcraft

2RU

Patch Panel Video switchcraft

2RU (MVPM)


Click here to view complete patchbay dimensions
(you will need to have Adobe Acrobat installed on your system to do this)

Patch Panel Video switchcraft


Individual MidSize Video Jacks

Patch Panel Video switchcraft

 

Midsize Video Jack Part Numbers and Options
 

Park Number Type Jack Configuration Captive Screws
MVJ75TZ Dual Normaled/75 Ohm Term. No
MVJN75TZ Dual Non-Normal/75 Ohm Term. No
MVJNNTZ Dual Non-Normal/Non-Term. No
MVJNTZ Dual Normal/Non-Term. No
17J5601Z Dual Normaled/75 Ohm Term. Yes
17J5602Z Dual Normal/Non-Term. Yes
17J5603Z Dual Non-Normal/75 Ohm Term. Yes
17J5604Z Dual Non-Normal/Non-Term. Yes
MVJSL75T Single/Long 75 Ohm Term. No
MVJSLNT Single/Long Non-Term. No
MVJSS75T Single/Short 75 Ohm Term. No
MVJSSNT Single/Short Non-Term. No
MVJSL75TCS Single/Long 75 Ohm Term. Yes
MVJSLNTCS Single/Long Non-Term. Yes
MVJSS75TCS Single/Short 75 Ohm Term. Yes
MVJSSNTCS Single/Short Non-Term. Yes

Electrical
Rated Bandwidth: 3.0 GHz
Characteristic Impedance: 75 ohms
Return Loss: See Typical Return Loss Chart
Insertion Loss: See Typical Insertions Loss Chart
Contact Resistance: Less than 20 milliohms
Termination Resistance: 75 ohm ±1%
Center Conductor: Accepts .048 pin diameter

Mechanical
Mechanical Shock: Per MIL-STD-202, Method 213, Test condition I
Vibration: Per MIL-STD-202, Method 201
Life Cycle: 30,000

Material
Dual Housings: Zinc alloy, nickel plated
Single Housing: Milled brass, nickel plated
Center Contacts: Copper alloy, gold plated
Switching Springs: Copper alloy, gold plated
Grounding Contacts: Copper alloy, gold plated
BNC Insulators: Teflon
Actuators: Thermoplastic, UL 94V-0 rated

Environmental
Operating Temperature: – 40ºC to 65ºC
Storage Temperature: – 55ºC to 85ºC
Thermal Shock: Per MIL-STD-202, Method 107
Moisture and Humidity: Per MIL-STD-202, Method 106